product

Power Range : 5 – 10 KVA

The HELIOS RT 11 UPS model is equipped with innovative features:

  • On-line double conversion
  • 3-level battery charger to optimize battery life and efficiency
  • Output and input power factor at 0.9
  • Returns higher than 94% in online mode
  • Extended autonomy by using additional battery cabinets
  • Large tolerance range for input voltage in order to avoid using the batteries and preserving autonomy
  • Possibility of putting up to 4 UPS in parallel

Advantages

  • Multi-function LCD display
  • High power factor and low THDI
  • ECO function option to increase returns
  • Power generator compatible
  • Possibility of putting up to 4UPS in parallel
  • Common or separate batteries for parallel system
  • Configurable number of batteries
  • Automatic battery test configuration
  • Multi-branch battery configuration
  • Different communication systems
  • Battery start
  • Emergency stop function

GENERAL FEATURESHELIOS RT 11 - 5HELIOS RT 11 - 6HELIOS RT 11 - 8HELIOS RT 11 - 10
Power rating (KVA/KW)5 / 4.56 / 5.48 / 7.210 / 9
TechnologyOn-line double conversion
INPUT FEATURES
Voltage220/230/240Vac (1P + N)
Frequency50 Hz : 45 à 55 Hz ou 60 Hz 55 à 65 Hz Auto-détection
Voltage range160-278 Vac
Power factor≥ 0.99
TDHI≤ 3 % to 100% with linear charge ≤ 5 % to 100% with non-linear charge
ConnectionTo a terminal
OUTPUT FEATURES
Voltage200/230/240Vac (1P + N)
Frequency50 ou 60 (± 0,1) Hz
Crest factor3 :1
Voltage regulation+/- 1%
THDu≤ 2% with linear charge ≤ 5% with non-linear charge
Return (in online mode)92%94%
BY-PASS STATIQUE
TypeAutomatic By-pass
Voltage range and frequencyStandard (+15% / -45%) Configurable (+5%, +10%, +25%) / (-20%, -30%) Frequency ± 10%

Frequency ± 10%
COMMUNICATION AND DISPLAY
DisplayLCD for indicating measurements
Lights for indicating operational status
Emergency stop switchAvailable
Communication portsRS 232 / USB
ENVIRONMENT
Operating temperature0° to 25°C
Noncondensing relative humidity0 to 90%
Sound level at 1m< 55 dB
CERTIFICATIONS
Standards and markingsCE / IEC 62040-2 et EN/IEC 62040-1-1
OPTIONS
CommunicationSNMP Card and Dry Contacts Card (Paralleling Card included)
AccessoriesRail kit for 19'' rack mount
MAINTENANCE BY-PASS
TypeOptional external by-pass
UPS BLOCKAGE
H x L x P (in mm)443 x 132 (3U) x 580 (Possible 19'' rail mounting)
Poids (en kgi23kg23kg25kg25kg
EXTERNAL BATTERY CABINET
Dimensions (L x H x W in mm)443 x 132 (3U) x 580 (Possible 19'' rail mounting)
Weight with battery (in Kg)67kg
Battery typeSealed lead batteries without maintenance VRLA Technology
Recharge time5 hours
Recharge current10 A max
AUTONOMY
In mn25201310

Autonomy: Other autonomies: Consult Us.

Note: Non-contractual document. The technical specifications mentioned in this document are subject to change without notice from us.